USA SALES ONLY

Southeastern Automation, Inc.
PO Box 22820
Knoxville, TN 37933-0820
Phone: (865) 675-3080
Fax: (865) 675-3060
www.southeastern-automation.com

Southeastern Automation Product Sheet

 

Oxygen Analyzers

Delta F manufactures an oxygen sensor that is unique to any other in that it is an electrochemical sensor that does not deplete over time.  Yes, it is true.  No more sensor replacements when you use Delta F.  In addition, the sensor comes to you factory calibrated and it stays that way.  Frequent calibrations are not required.


ONLY DELTA F NON-DEPLETING SENSORS PROVIDE THE FOLLOWING:

  • Every analyzer is factory calibrated and READY TO USE. • • • •
  • The non-depleting sensor REQUIRES LITTLE OR NO RE-CALIBRATION over time.
  • Five year sensor warranty. NO PERIODIC SENSOR REPLACEMENTS.
  • With the Stab-El™ option, NO ACID SCRUBBING IS REQUIRED for trace levels.


NEW E-Sensors

E Sensor Technical Bulletin DF-300E Series Brochure

Other Oxygen Sensors
M Sensor Technical Bulletin Solid State Sensor Technical Bulletin

Oxygen Analyzers

NEW 100E SERIES

DF-110E

The DF-110E offers a flexible and cost-effective way to include superior oxygen analysis in your OEM system. The DF-110E is calibrated to standards traceable to NIST and operated for several days to ensure flawless performance out-of-the-box. Depending on the application, the sensor can operate for years without recalibration and requires only the occasional addition of distilled water for maintenance..
DF-110E Product Sheet
DF-110E Configuration & Spec Sheet
DF-110E Manual
DF-110E FAQs
DF-110E Spare Parts

DF-130E

The DF-130E is configured to provide you with a reliable, dependable and accurate oxygen analyzer at a price you can afford. Just take it out of the carton and start operating. Options include – oxygen alarm, sample pump, STAB-EL™ acid gas system, CE certification.
DF-130E Product Sheet
DF-130E Configuration & Spec Sheet
DF-130E Manual
DF-130E FAQs
DF-130E Spare Parts

DF-140E

The DF-140E allows for reliable oxygen measurement in a wide variety of environments, including outdoors and in explosive environments with a NEMA 7 remote sensor enclosure. Using the revolutionary non-depleting E-Sensor, the DF-140E delivers reliable readings without frequent recalibration and periodic sensor replacement.
DF-140E Product Sheet
DF-140E Configuration & Spec Sheet
DF-140E Manual
DF-140E FAQs
DF-140E Spare Parts

DF-150E

Every DF-150E is custom configured under ISO-9001 controls to your precise specifications and calibrated to standards traceable to NIST and operated for several days to ensure flawless performance. The ultra-stable E-Sensor can operate for years without re-calibration giving you a long and useful life.
DF-150E Product Sheet
DF-150E Configuration & Spec Sheet
DF-150E Manual
DF-150E FAQs
DF-150E Spare Parts
NEW 300E SERIES

DF-310E

Flexible, Adaptable Oxygen Analyzer The DF-310E with the E-Sensor is ready to handle your oxygen analysis needs in almost any application.

The DF-310E features:
  • Accuracy – the greater of ±3 reading or ±0.02% range
  • Ranges from 0-0.5ppm to 25%
  • Instantaneous response to oxygen change
  • Fast response – typically less than 10 seconds to read 90% of a step change
  • Background gas compatibility including N2, H2, Co, freons, hydrocarbons, and more
  • STAB-EL™ option removes acids and ionic impurities from the electrolyte that could affect sensor performance
  • Optional battery back-up for extended use and process protection
DF-310E Product Sheet
DF-310E Configuration & Spec Sheet
DF-310E Manual
DF-310E FAQs
DF-310E Spare Parts

DF-320E

The DF-320E brings improved performance to harsh and hazardous environments. It is specifically designed for:
  • Class I, Div 2, Groups A,B,C,D, CSA and CENELEC Zone 2 certification
  • Perfect for any application where potential explosion is a possibility – for example in natural gas lines or LNG storage, etc.
DF-320E Product Sheet
DF-320E Configuration & Spec Sheet
DF-320E Manual
DF-320E FAQs
DF-320E Spare Parts

DF-330E

The The DF-330E provides an ideal oxygen analyzer for many industrial applications where very fast response is critical. Using a unique solid state coulometric sensor with a solid electrolytre, it delivers fast response across a broad measurement range.

The DF-330E features:
 
  • Exceptionally fast response – ppm levels from air in 5 minutesIn-situ or in-flow mounting capabilitiesQuick recovery down to low levels after exposure to airGood low-end sensitivity plus a wide measurement rangeConsistent accuracy from sub-atmospheric pressure to 100 psig
  • Range up to 100%
DF-330E Product Sheet
DF-330E Configuration & Spec Sheet
DF-330E Manual
DF-330E FAQs
DF-330E Spare Parts

DF-340E

The DF-340E is tough and durable - protected by a dust proof, waterproof, explosion proof, enclosure, they also offer the option of remoting the sensor in a NEMA 4 enclosure.

The DF-340E features:
  • NEMA 4x version of the DF-310EIdeally suited for harsh environments
  • Sensor and flowmeter can be mounted in the analyzer enclosure or remoted in a NEMA 4 enclosure

DF-340E Product Sheet
DF-340E Configuration & Spec Sheet
DF-310E Manual
DF-310E FAQs
DF-310E Spare Parts

DF-370E

Designed for the Dirty Work

The DF-370E is tough and durable - protected by a dust proof, waterproof, explosion proof, enclosure, they also offer the option of remoting the sensor in a NEMA 7 enclosure.

The DF-370E features:
  • NEMA 7x version of the DF-310E
  • Sensor and flowmeter can be mounted in the analyzer enclosure or remoted in a Nema 7 enclosure.
DF-370E Product Sheet
DF-370 Configuration & Spec Sheet
DF-310E Manual
DF-310E FAQs
DF-310E Spare Parts


NEW NANOTRACE ANALYZERS

DF-550E

NanoTrace provides a reliable Low-detection-level of 200 ppt in a compact, easy to use analyzer.  The superior NanoTrace performance has been verified by a host of independent third parties such as Air Products and Chemicals Inc.  Part of the extensive APIMS testing is shown.  Every NanoTrace is manufactured under ISO 9001 control and is calibrated and operated for five weeks to ensure a fast and accurate start-up at your site.

DF 550E
DF-550E Manual
DF-550E FAQs
DF-550E Spare Parts

DF-560E

NanoTrace II provides the lowest LDL in the industry.  Part of the extensive APIMS testing by several third parties, including SAES Pure Gas Inc., is shown.  NanoTrace II is an extension of the first NanoTrace used in semiconductor fabs and analytical carts around the world.  It features a lower LDL, Data Graphing, Scheduled Automatic Calibrations, Automated Maintenance Logging, and a variety of other new capabilities.  Every NanoTrace is manufactured under ISO 9001 control and is calibrated and operated for five weeks to ensure a fast and accurate start-up at your site.
DF-560E
DF-560E Manual
DF-560E FAQs
DF-560E Spare Parts

Delta F Page